malfunction potential problem solution
Platform cannot lift
■ The ground selective switch is not in the correct position
■ Select the switch to the platform position
■ Platform overload
■ Remove some weight
■ Lift button operation error
■ Reset button
■ Panel wiring is worn
■ Repair or replace the connection cable
■ Battery is dead
■ Recharge
■ Check line voltage
■ Repair or replace wiring
Electric pump does not work
■ The reset button does not work
■ Check whether the power cord is tight
■ The battery is dead or damaged
■ Repair or replace the contactor
■ Battery connection is bad
■ Recharge or replace the battery

■ Clean and tighten the plug end
Insufficient voltage
■ Hydraulic pump does not work properly
■ Repair or replace the pump
■ Component pressure needs calibration
■ Calibration (contact after sales service)
■ Leakage of hydraulic oil in wiring points, pipes or components
■ Repair or replacement
■ Failure of hydraulic components
■ Replacement parts (contact after-sales service provider)
Hydraulic pump noise
■ Insufficient hydraulic oil
■ Replenish hydraulic oil (don't overfill)
■ Damaged or loose pipes or connectors
■ Repair, tighten or replace